Digital Temperature Controller E5CC. Refer to your OMRON website for the most recent information on applicable safety standards. Sensor Input. E5@C Digital Temperature Controllers User’s Manual (Cat. H174) E5@C Digital Temperature Controllers Communications Manual (Cat. H175) E5CC 3. Omron E5CC-800 Multifunction Controllers Description The E5CC-800, which set new global standards in the crucial areas of precision, user friendliness and control performance.
- Omron E5cc Rx2asm 800 User Manual Free
- Omron Temperature Controller E5cc Manual
- E5cc Rx2asm 802
- Omron E5cc Rx2asm 800 User Manual Pdf
- Omron E5cc Rx2asm 800 User Manual Software
- Home>
- Products>
- Product Category>
- Control Components>
- Temperature Controllers>
- General-purpose>
- E5CC, E5CC-B, E5CC-U
48 x 48 mm. Large White PV Display That's Easier to Read. Easy to Use, from Model Selection to Setup and Operation. A Complete Range of I/O Capacities, Functions, and Performance. Handles More Applications. E5CC-B is our Value Design product which increase the value of your control panel.
about this Product Family
Related Contents
- Common
- Temperature Controllers
last update: October 2, 2017
Model Number Legend
Models with Screw Terminal Blocks
Heating and Cooling Control
Using Heating and Cooling Control
(1) Control Output Assignment
If there is no control output 2, an auxiliary output is used as the cooling control output.
If there is a control output 2, the two control outputs are used for heating and cooling.
(It does not matter which output is used for heating and which output is used for cooling.)
(2) Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
Models with Push-In Plus Terminal Blocks
Heating and Cooling Control
Using Heating and Cooling Control
(1)Control Output Assignment
An auxiliary output is used as the cooling control output.
(2) Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
Plug-in Models
Control output | No. of auxiliary outputs | Options | Model | Model | ||
---|---|---|---|---|---|---|
HB alarm and HS alarm | No. of event inputs | Communica- tions | Power supply voltage | Power supply voltage | ||
100 to 240 VAC | 24 VAC/DC | |||||
Relay output | --- | --- | --- | --- | E5CC-RW0AUM-000 | E5CC-RW0DUM-000 |
1 | E5CC-RW1AUM-000 | E5CC-RW1DUM-000 | ||||
2 | E5CC-RW2AUM-000 | E5CC-RW2DUM-000 | ||||
Voltage output (for driving SSR) | --- | --- | --- | --- | E5CC-QX0AUM-000 | E5CC-QX0DUM-000 |
1 | E5CC-QX1AUM-000 | E5CC-QX1DUM-000 | ||||
2 | E5CC-QX2AUM-000 | E5CC-QX2DUM-000 | ||||
Linear current output | --- | --- | --- | --- | E5CC-CX0AUM-000 | E5CC-CX0DUM-000 |
1 | E5CC-CX1AUM-000 | E5CC-CX1DUM-000 | ||||
2 | E5CC-CX2AUM-000 | E5CC-CX2DUM-000 |
Heating and Cooling Control
Using Heating and Cooling Control
(1) Control Output Assignment
An auxiliary output is used as the cooling control output.
(2) Control
If PID control is used, you can set PID control separately for heating and cooling.
This allows you to handle control systems with different heating and cooling response characteristics.
Optional Products (Order Separately)
USB-Serial Conversion Cable
Terminal Covers (for E5CC)
Omron E5cc Rx2asm 800 User Manual Free
Note: The E53-COV10 cannot be used.
Htc explorer a310e user manual pdf file. Refer to Data Sheet for the mounted dimensions. Free drz400sm shop manual download free full.
Waterproof Packing
Note: The Waterproof Packing is provided only with E5CC/E5CC-B Controllers.
The E5CC-U cannot be waterproofed even if the Waterproof Packing is attached.
Current Transformers (CTs)
Hole diameter | Model |
---|---|
5.8 mm | E54-CT1 |
5.8 mm | E54-CT1L * |
12.0 mm | E54-CT3 |
12.0 mm | E54-CT3L * |
* Lead wires are included with these CTs. If UL certification is required, use these CTs.
Adapter
Omron Temperature Controller E5cc Manual
Note: Use this Adapter when the panel has already been prepared for an E5B[] Controller.
Waterproof Cover
Mounting Adapter
Note: This Mounting Adapter is provided with the Digital Temperature Controller.
DIN Track Mounting Adapter (for E5CC)
Sockets (for E5CC-U)
Type | Model |
---|---|
Front-connecting Socket | P2CF-11 |
Front-connecting Socket with Finger Protection | P2CF-11-E |
Back-connecting Socket | P3GA-11 |
Terminal Cover for Back-connecting socket with Finger Protection | Y92A-48G |
Front Covers
Type | Model |
---|---|
Hard Front Cover | Y92A-48H |
Soft Front Cover | Y92A-48D |
CX-Thermo Support Software
E5cc Rx2asm 802
CX-Thermo version 4.61 or higher is required for the E5CC-U.
CX-Thermo version 4.65 or higher is required for the E5CC-B.
CX-Thermo version 4.67 or higher is required for the E5CC-B linear current output type.
For the system requirements for the CX-Thermo, refer to information on the EST2-2C-MV4.
last update: October 2, 2017
Omron E5cc Rx2asm 800 User Manual Pdf
Product Category
Omron E5cc Rx2asm 800 User Manual Software
- Control Components
- Temperature Controllers
- General-purpose
- E5CC, E5CC-B, E5CC-U
- General-purpose
- Temperature Controllers
© Copyright OMRON Corporation 2007 - 2019. All Rights Reserved.