Comfort Aire Dehumidifier User Manual Bhd-301-d

Buy Genuine Dehumidifier Parts for Comfort-aire BHD-301-D. It's Easy to Owner's Manuals for Comfort-aire BHD-301-D: Owner's Manual (General) (pdf). Room air conditioners repair & replacement parts at Sears PartsDirect. Find parts, manuals & diagrams for any Comfort Aire room air conditioners repair project. Testul rde manual comfort 92 gas. View and Download Heat Controller Comfort-Aire BHD-301-D service manual online. Comfort-Aire BHD-301-D Dehumidifier pdf manual download. Also for: Comfort-aire bhd-501-d, Comfort-aire bhd-651-d. Heat Controller Comfort-Aire BHD-501-D Manuals & User Guides. User Manuals, Guides and Specifications for your Heat Controller Comfort-Aire BHD-501-D Dehumidifier. Database contains 3 Heat Controller Comfort-Aire BHD-501-D Manuals (available for free online viewing or downloading in PDF): Service manual, Owner's manual. Recent Comfort-Aire BHD-501 Dehumidifier questions, problems & answers. Free expert DIY tips, support, BHD-501 D Manual Comfort-Aire/ Posted. The Ultra-Aire 100V is a whole house ventilating dehumidifier that is integrated into the heating and ultimate in comfort, health and property protection through. Buy Genuine Dehumidifier Parts for. Heat Controller Comfort-Aire BHD-501-D Owners Manual Owner's manual (52 pages). Haier HD458 User Manual Operation & user’s manual. View online Service manual for Heat Controller BHD-301-D Dehumidifier or simply click Download button to examine the Heat Controller BHD-301-D guidelines offline on your desktop or laptop computer. Home Comfort-Aire Residential A/C & Heat Pumps Replacement Parts Manufactured Home Furnace. Room Air & Dehumidifiers PTACs/PTHPs Toggle Search. Search: Search.

Burners and Venturi

Ref.ImagePart No & DescriptionPrice
162615CMF6877A30013L - Sensor Assy
View Part Info
$53.80

View and Download Heat Controller BHD-301-G service manual online. Portable Dehumidifer Series with R-410A. BHD-301-G Dehumidifier pdf manual download. Also for: Bhd-501-g, Bhd-651-g.

Capacitors

Ref.ImagePart No & DescriptionPrice
0CZZA20005J - Capacitor 35 Mfd-370v
View Part Info
$21.88

Chargers and Cords

Ref.ImagePart No & DescriptionPrice
264110CMF6411A20001Z - Power Cord
View Part Info
$29.71

Circuit Boards

Ref.ImagePart No & DescriptionPrice
268712CMF6871A202898 - Pwb Pcb Assembly,disptay
View Part Info
$0.00 More Info
268714CMF6871A10124A - Pwb Pcb Assembly,main
View Part Info
$0.00 More Info

Compressors

Ref.ImagePart No & DescriptionPrice
554160CMF2521C-A8626 - Compressor
View Part Info
$250.80

Condensers

Ref.ImagePart No & DescriptionPrice
5403A10008B - Condenser Assy, Firstqb# Cndsr008b
Quantity: 1
View Part Info
$40.46
5540305403A10008N - Condenser
Quantity: 1
View Part Info
$32.69
554030CMF5403A10008N - Condenser
View Part Info
$61.04

Controls

Ref.ImagePart No & DescriptionPrice
6877A30013S - Sensor Assembly
View Part Info
Not Available
More information
130411CMF3041A10042C - Base Assembly
View Part Info
$0.00 More Info
135312CMF3531A10285D - Front Grille Assy
View Part Info
$61.04
148390CMF4839A10002A - Tank Assembly.bucket
View Part Info
$0.00 More Info
149410CMF4941A300198 - Knob Assembly
View Part Info
$0.00 More Info
235512EBR74780403 - Pcb Assy,mai
View Part Info
$63.14
249950CMF4995A20359J - Control Box Assy
View Part Info
$81.58
2660026600FX5001G - Rocker Switch Qb# Sw5001g
Quantity: 1
View Part Info
Not Available
More information
266002CMF6600FX5001G - Switch.rocker
View Part Info
$0.00 More Info
2660036601A30006A - Switch Asy
Quantity: 1
View Part Info
Not Available
More information
266011CMF6600A30003C - Micro Switch
View Part Info
Not Available
More information
2687126871A20289B - Pwb
Quantity: 1
View Part Info
Not Available
More information
268714EBR39204301 - Pwb (pcb) -main Asmqb#pcb142a
Quantity: 1
View Part Info
$99.99
330870CMF3087A100198 - Drain Pan Assembly
View Part Info
$0.00 More Info
354210CMF5421A10009P - Evap Assy
View Part Info
$90.06
558511CMF5851A30001A - Drier Assy
View Part Info
$40.08
667482CMF6748C-0003D - Ptc Assy
View Part Info
$24.88

Covers

Ref.ImagePart No & DescriptionPrice
235512CMF3551A20122A - Display Cover
View Part Info
$36.40

Filters

Ref.ImagePart No & DescriptionPrice
152302KK1000 - Filter With Grid, Cut To Fit 15 X 24
Quantity: 1
View Part Info
$15.03 More Info
152302CMF5230A20040A - Filter Mech ,air
View Part Info
$0.00 More Info

Handles

Ref.ImagePart No & DescriptionPrice
1494104941A30019B - Control Knob
Quantity: 1
View Part Info
$6.78
4365003650A20004A - Handle
Quantity: 1
View Part Info
$4.68
436500CMF3650A20004A - Handle
View Part Info
$7.76

Motors and Blades

Ref.ImagePart No & DescriptionPrice
3468114681A20040J - Motor For Goldstar / Lgqb#mtr040j
Quantity: 1
View Part Info
Not Available
More information
346811CMF4681A20040J - Motor
View Part Info
$0.00 More Info
349600CMF4960A20009B - Motor Mount
View Part Info
$24.88
3590125900A20007B - Fan
Quantity: 1
View Part Info
$7.59
359012CMF5900A20007A - Fan.turbo
View Part Info
$0.00 More Info

Instruction Manual

Manual

Other Parts

Ref.ImagePart No & DescriptionPrice
4999A10002A - Shroud Asy
Quantity: 1
View Part Info
$14.42
3087A10019C - Drain Pan
Quantity: 1
View Part Info
$55.91
6750U-L082A - Protector
Quantity: 1
View Part Info
Not Available
More information
4995A20359U - Cont Box
Quantity: 1
View Part Info
$55.71
1304113041A10042C - Base Assembly.
View Part Info
$0.00 More Info
1309003090A10042B - Cabinet
Quantity: 1
View Part Info
$36.07
130900CMF3090A10042A - Cabinet
View Part Info
$67.31
144410CMF4441A30001B - Caster
View Part Info
$7.76
1499804998A10034A - Shroud
Quantity: 1
View Part Info
$14.42
149980CMF4998A10034A - Shroud
View Part Info
$30.72
2383103831A20079G - Escutcheon Qb# Escutn079g
Quantity: 1
View Part Info
$11.40
238310CMF3831A20079G - Escutcheon
View Part Info
$19.76
2499504995A20359J - Control Box Assy, Single# Cntrl359j
Quantity: 1
View Part Info
$66.40
3308703087A10019B - Drain Pan Assembly Qb# Pan019b
Quantity: 1
View Part Info
$28.26
3496004999A10002B - Mount
Quantity: 1
View Part Info
$12.47
3542105421A10009P - Evap Assy,first Qb#evap009p
Quantity: 1
View Part Info
$49.75
435300CMF3530A10193A - Rear Grille
View Part Info
$0.00 More Info
5501405040AR4195A - Rubber
Quantity: 1
View Part Info
$4.36
550140CMF5-040AR4195A - !solator.comp
View Part Info
$0.00 More Info
5541602521C-A8626 - Re-compres
View Part Info
$180.07
5585115851A30001A - Drier Assy
View Part Info
$10.85
5675026750C-0009E - O.l.p.
Quantity: 1
View Part Info
$16.24
567502CMF6750C-0009E - Overload
View Part Info
$29.71
6674826748C-0003D - P.t.c. Asy
View Part Info
$12.47
752140CMF5214A20027A - Hose.connector
View Part Info
$0.00 More Info

Panels

Ref.ImagePart No & DescriptionPrice
1353123531A10285D - Grille Asm
Quantity: 1
View Part Info
$40.45
4353003530A10193B - Rr Grille
View Part Info
$14.42

Tubing

Ref.ImagePart No & DescriptionPrice
35211ACMF5211A10464A - Suction Tube Assy
View Part Info
$38.85
35211A?5211A10464A - Tube Assembly,suction .
View Part Info
$0.00 More Info
3521135211A11019A - Dschrg Tube
View Part Info
$9.95
352113CMF5211A11019A - Discharge Tube Assy
View Part Info
$19.76
5521115211A30720A - Tube Assembly,capillary .
View Part Info
$0.00 More Info
552111CMF5211A30720A - Cap Tube Assy
View Part Info
$19.76
7521405214A20027A - Drainhose Cnctroption#hsecntr027a
Quantity: 1
View Part Info
Not Available
More information

Water Tanks

Ref.ImagePart No & DescriptionPrice
1483904839A10001D - Tank Assy Bucket (bukt001d)qb#bukt001d
Quantity: 1
View Part Info
Not Available
More information
Summary of the content on the page No. 1

SERVICE MANUAL
Portable Dehumidifer Series
with R-410A:
BHD-301-G
BHD-501-G
BHD-651-G
Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.com

Summary of the content on the page No. 2

BHD-G Service Manual Portable Dehumidifier with R-410A Heat Controller, Inc. TABLE OF CONTENTS 1. PREFACE .............................................. 2 1.1 SAFETY PRECAUTIONS ........................... 2 1.2 INSULATION RESISTANCE TEST .................... 2 1.3 UNIT FEATURES .................................. 2 1.4 CONTROL LOCATIONS ..................

Summary of the content on the page No. 3

Heat Controller, Inc. Portable Dehumidifier with R-410A BHD-G Service Manual 1. PREFACE This SERVICE MANUAL provides various servicing information for the unit, including the mechanical and electrical parts, etc. This dehumidifier was manufactured and assembled under a strict quality control system. The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit. 1.1 SAFETY PRECAUTIONS 1. When servicing the unit, set the POWER SWITCH to OFF and U

Summary of the content on the page No. 4

BHD-G Service Manual Portable Dehumidifier with R-410A Heat Controller, Inc. 3. Humidity Set Control The humidity level can be set within a range of 35%RH (Relative Humidity) to 85%RH (Relative Humidity) in 5% increments. For drier air, press the button and set to a lower percent value(%). When the value displays 35%,press the button again will activate the continuous dehumidifying operation. For damper air, press the button and set a higher percent value(%). TIMER Set Control

Summary of the content on the page No. 5

Heat Controller, Inc. Portable Dehumidifier with R-410A BHD-G Service Manual 2. Product Installation Instructions Install the portable dehumidifier in a flat and spacious location where the air outlets will not be obstructed. Do not install underneath desks or inside cupboards as this will restrict the air flow. 16in (40cm) or more Maintain a clearance of at least 8 inches (20cm) in the front and rear of the unit to maintain correct air-flow. 3. Product Operation 8in (20cm) or more 8in

Summary of the content on the page No. 6

BHD-G Service Manual Portable Dehumidifier with R-410A Heat Controller, Inc. 3.4 OPERATION WITH CONTINUOUS DRAINAGE On the rear of the unit, remove the rubber plug carefully. Remove the water tank first, then push the hose onto the connector located inside of the hole. The hose should go down smoothly without bends or kinks. Place the end of the hose into a suitable drainage location for condensate removal. 3.5 MAINTENANCE 3.5.1 Precaution Be sure to unplug the unit before cleaning. Do not use

Summary of the content on the page No. 7

Heat Controller, Inc. Portable Dehumidifier with R-410A BHD-G Service Manual 4.Electronic function 4.1 POWERING ON THE UNIT When the unit is just powered on or the dropped power is just restored, the unit will immediately perform the self- diagnosis. The check items include the water-full, temperature sensor and humidity sensor. If there is no defect, the power LED will flash at 0.5Hz while all other LEDs are off. All buttons are invalid except the ON/OFF button. 4.2 SETTING THE RELATIVE HUMID

Summary of the content on the page No. 8

BHD-G Service Manual Portable Dehumidifier with R-410A Heat Controller, Inc. 5.Basic Test Procedures 5.1 DEFECTIVE COMPRESSOR Compressors are single phase, 115 volt. All compressor motors are permanent split capacitor type using only a running capacitor across the start and run terminal. All compressors are internally spring mounted and externally mounted on rubber isolators. COMPRESSOR WINDING TEST Remove compressor terminal box cover and disconnect wires from terminals. Using an ohmmeter, c

Summary of the content on the page No. 9

Heat Controller, Inc. Portable Dehumidifier with R-410A BHD-G Service Manual TERMINAL OVERLOAD (Internal) Some model compressors are equipped with an internal overload. The overload is embedded in the motor windings to sense the winding temperature and/or current draw. The overload is connected in series with the common motor terminal. Should the internal temperature and/or current draw become excessive, the contacts in the overload will open, turning off the compressor. The overload will aut

Summary of the content on the page No. 10

Comfort Aire Dehumidifier User Manual Bhd-301-d Download

BHD-G Service Manual Portable Dehumidifier with R-410A Heat Controller, Inc. 11. Break vacuum by charging system from the high side with the correct amount of refrigerant specified. This will prevent boiling the oil out of the crankcase. NOTE: If the entire charge will not enter the high side, allow the remainder to enter the low side in small increments while operating the unit. 12. Restart unit several times after allowing pressures to stabilize. Pinch off lines, cut and solder the ends. Re

Summary of the content on the page No. 11

Heat Controller, Inc. Portable Dehumidifier with R-410A BHD-G Service Manual CAPACITOR - TEST 1. Remove capacitor from unit. 2. Check for visual damage such as bulges, cracks, or leaks. 3. For dual rated, apply an ohmmeter lead to common (C) terminal and the other probe to the compressor (HERM) terminal. A satisfactory capacitor will cause a deflection on the pointer, then gradually move back to infinity. 4. Reverse the leads of the probe and momentarily touch the capacitor terminals. The defl

Summary of the content on the page No. 12

BHD-G Service Manual Portable Dehumidifier with R-410A Heat Controller, Inc. 6. TROUBLESHOOTING GUIDE 6.1 TROUBLESHOOTING GUIDE In general, possible trouble is classified in three kinds. One is called Starting Failure which is caused from an electri- cal defect, another is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper applica- tion, and the other is called the Structure Damage. ROOM AIRCONDITIONER VOLTAGE LIMITS: NAMEPLATE RATING MINIMUM MAXIMUM 115V 1

Summary of the content on the page No. 13

Heat Controller, Inc. Portable Dehumidifier with R-410A BHD-G Service Manual 6.3.3 Humidity sensor check 6.3.4 Fail to start or fail to start motor 12

Summary of the content on the page No. 14

BHD-G Service Manual Portable Dehumidifier with R-410A Heat Controller, Inc. 6.3.5 Abnormal noise Check whether the lines are vibrating or coming into contact with other lines or compressor Check whether the noise is from inside the line. 6.3.6 Complaint and remedy Complaint Cause Remedy Transformer (Discharge Check resistance between the two input/output lines on transformer before transformer. Replace the transformer if either of the input/ No display or any button testing) output is op

Summary of the content on the page No. 15

Heat Controller, Inc. Portable Dehumidifier with R-410A BHD-G Service Manual Complaint Cause Remedy Replace the fan if cracked, out of balance, or partially Fan missing. Replace the blower if cracked, out of balance, or partially Blower missing. Fan motor noise Loose screws Tighten them. Replace the motor if knocking sounds continues when Worn bearings running, or if the motor hums or noise appears to be internal while running. Voltage Check voltage. Call an electrician if not within limits.

Go go elite scooter user manual download. Pride’s exclusive black, non-scuffing tires.

Summary of the content on the page No. 16

BHD-G Service Manual Portable Dehumidifier with R-410A Heat Controller, Inc. 7. Wiring Diagram 15

Summary of the content on the page No. 17

04/2009 05/2010